1. Design Studio 3.0 Manual
  2. Appendices
  3. Appendix A: Integrating Ketra Products into HomeWorks QS Systems

Additional Actions Available

Adding Ketra Devices in Ketra Design Studio

Note: On-site radio communication required to add Ketra devices.

N4 hubs

1. Click Organization and select the Add Hubs tab on the right pane.

2. Click Find New Hubs and add to the installation.

3. To set network settings, click the Device Settings tab and then click Settings for: Hubs.

4. Click Publish and Save.

5. In Lutron Designer, click Tools > Map Ketra Poject File > Import/Update Ketra Configurations.

Lamps and Luminaires

1. Click Organization and select the Add Devices tab on the right pane.

2. Click Find New Hubs and add to the installation.

3. Click Find New Devices and add the discovered devices to the appropriate groups.

4. Click Publish and Save.

5. In Lutron Designer, click Tools > Map Ketra Poject File > Import/Update Ketra Configurations.

Firmware Updates in Ketra Tech Tool

The Ketra devices may need the firmware version to be updated. This is accomplished via the Ketra Tech Tool. Firmware updates can take up to 4 hours to complete for a system with fully loaded N4 hubs; however, the initial update to the N4 hubs takes a lot less time. After the N4 hubs are updated, the Ketra Tech Tool can be closed and the computer can be disconnected from the network while the N4 hubs update the associated devices.

Ketra Design Studio cannot be opened while the Ketra Tech Tool is in use. If you want to keep the Ketra Tech Tool open to monitor the status of the updates, first build the Ketra groups, scenes, and shows in Ketra Design Studio before updating the firmware with the Ketra Tech Tool. Mapping, programming, and activation can be performed in Lutron Designer while the Ketra device firmware update is taking place.

1. Open the Tech Tool and select the installation.

2. The tool will show a list of all Ketra devices and their status

App.A 26


3. To update your device, select Upgrade from Control Device(s) from the drop-down on the left and then click Start.

App.A 27
Note: Once the initial upload to the N4s is complete (indicated by receiving the message below), the programming computer can be disconnected from the network and the Tech Tool can be closed.
App.A 28

Activating Lutron Devices

1. In Lutron Designer, click the activate tab and select processors from the drop down menu.

2. Activate the Lutron Connect bridge and all other desired devices.

Note: Select Save and Transfer when prompted before initial device activation, after any new devices are added, or after link assignments are changed.

Transfer

1. Go to the transfer tab in the HomeWorks QS Designer software.

2. Press Start Transfer.

Test

After programming is complete, walk around and check that all devices are working as expected.